1.
J Biomech Eng ; 145(2)2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35972803

RESUMO

The hearing contact lens® (HCL) is a new type of hearing aid devices. One of its main components is a piezo-electric actuator. In order to evaluate and maximize the HCL's performance, a model of the HCL coupled to a middle-ear model was developed using finite element approach. The model was validated step by step starting with the HCL only. To validate the HCL model, vibrational measurements on the HCL were performed using a laser-doppler-vibrometer (LDV). Then, a silicone cap was placed onto the HCL to provide an interface between the HCL and the tympanic membrane of the middle-ear model, and additional LDV measurements on temporal bones were performed to validate the coupled model that was used to evaluate the equivalent sound pressure of the HCL. Moreover, a de-eper insight was gained into the contact between the HCL and tympanic membrane and its effects on the HCL performance. The model can be used to investigate the sensitivity of geometrical and material parameters with respect to performance measures of the HCL and evaluate the feedback behavior.


Assuntos
Orelha Média , Membrana Timpânica , Análise de Elementos Finitos , Silicones , Som , Vibração
2.
Eur Arch Otorhinolaryngol ; 272(3): 563-71, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24381023

RESUMO

A dehiscence of the superior semicircular canal is said to be responsible for a number of specific and unspecific ear symptoms and possible a conductive hearing loss of up to 40 dB. As in vivo a dehiscence would not be opened against air, but is naturally patched with dura and the brain, it was our aim to investigate the effects of an superior semicircular canal dehiscence on the air conduction hearing in fresh human temporal bones with different boundary conditions. At ten fresh human temporal bones, we investigated the transmission of sound energy through the middle and inner ear using a round window microphone and laser Doppler vibrometer for perilymph motions inside the dehiscence. After baseline measurements, the superior semicircular canal was opened. We investigated the change of the transfer function when the canal is opened against air (pressure equivalent water column), against a water column and when it is patched with a layer of dura. Opening the superior semicircular canal resulted in a loss of sound transmission of maximal 10-15 dB only in frequencies below 1 kHz. When covering the dehiscence with a water column, the conductive hearing component was reduced to 6-8 dB. Placing a dura patch on top of the dehiscence resulted in a normalization of the transfer function. If our experiments are consistent with the conditions in vivo, then superior semicircular canal dehiscence does not lead to an extensive and clinically considerable conductive air conduction component.


Assuntos
Perda Auditiva Condutiva/fisiopatologia , Canais Semicirculares/fisiopatologia , Acústica , Orelha Média/fisiopatologia , Testes Auditivos/métodos , Humanos , Som , Osso Temporal , Vibração
3.
J Acoust Soc Am ; 136(4): 1756-67, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25324078

RESUMO

The annular ligament provides a compliant connection of the stapes to the oval window. To estimate the stiffness characteristics of the annular ligament, human temporal bone measurements were conducted. A force was applied sequentially at several points on the stapes footplate leading to different patterns of displacement with different amounts of translational and rotational components. The spatial displacement of the stapes footplate was measured using a laser vibrometer. The experiments were performed on several stapes with dissected chain and the force was increased stepwise, resulting in load-deflection curves for each force application point. The annular ligament exhibited a progressive stiffening characteristic in combination with an inhomogeneous stiffness distribution. When a centric force, orientated in the lateral direction, was applied to the stapes footplate, the stapes head moved laterally and in the posterior-inferior direction. Based on the load-deflection curves, a mechanical model of the annular ligament was derived. The mathematical representation of the compliance of the annular ligament results in a stiffness matrix with a nonlinear dependence on stapes displacement. This description of the nonlinear stiffness allows simulations of the sound transfer behavior of the middle ear for different preloads.


Assuntos
Ligamentos/fisiologia , Modelos Biológicos , Janela do Vestíbulo/fisiologia , Estribo/fisiologia , Fenômenos Biomecânicos , Elasticidade , Humanos , Técnicas In Vitro , Movimento , Dinâmica não Linear , Pressão , Estresse Mecânico , Osso Temporal/fisiologia , Fatores de Tempo
4.
J Acoust Soc Am ; 132(5): 3280-91, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23145612

RESUMO

The piston-like (translation normal to the footplate) and rocking-like (rotation along the long and short axes of the footplate) are generally accepted as motion components of the human stapes. It has been of issue whether in-plane motions, i.e., transversal movements of the footplate in the oval window, are comparable to these motion components. In order to quantify the in-plane motions the motion at nine points on the medial footplate was measured in five temporal bones with the cochlea drained using a three-dimensional (3D) laser Doppler vibrometer. It was found that the stapes shows in-plane movements up to 19.1 ± 8.7% of the piston-like motion. By considering possible methodological errors, i.e., the effects of the applied reflective glass beads and of alignment of the 3D laser Doppler system, such value was reduced to be about 7.4 ± 3.1%. Further, the in-plane motions became minimal (≈ 4.2 ± 1.4% of the piston-like motion) in another plane, which was anatomically within the footplate. That plane was shifted to the lateral direction by 118 µm, which was near the middle of the footplate, and rotated by 4.7° with respect to the medial footplate plane.


Assuntos
Movimento , Estribo/fisiologia , Estimulação Acústica , Fenômenos Biomecânicos , Efeito Doppler , Humanos , Lasers , Modelos Anatômicos , Modelos Biológicos , Pressão , Rotação , Estribo/anatomia & histologia , Vibração
SELEÇÃO DE REFERÊNCIAS